The Greenstar I by Worcester Bosch is a "Smart Boiler". This boiler has more sensors and electronic inputs which lets it provide us with a more accurate description of what is going on. Unlike have 1 error code which may cover many issues, the Greenstar I has an error code for everything. This helps us diagnose problems fatser and saves you money!




Error Code: 226


Cause: Service tool has been connected in the blocking error history menu. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Service menu option.




Error Code: FD 231


Cause: The power has been interrupted during a lockout. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Site visit required.




Error Code: C7 214


Cause: Fan does not run during the start up phase. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Fan harness connector needs checking and leads need checking.




Error Code: C6 215


Cause: Fan speed too high. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Test fan, harness and leads.




Error Code: C7 216


Cause: Fan speed too low. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Test fan, harness and leads.




Error Code: C7 217


Cause: Fan has stopped during appliance operation. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Test fan, harness and leads.




Error Code: C1 264


Cause: Fan stopped during operation. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Test fan, harness and leads.




Error Code: C4 273


Cause: Continuous fan operation for the last 24 hours. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Enginner to check fan and PCB.




Error Code: E2 222


Cause: Flow temperature sensor shorted. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Check for blockages.




Error Code: E2 233


Cause: Flow temperature sensor disconnected. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Check lead and connections on sensor.




Error Code: E9 276


Cause: Primary flow temperature exceeded 95°c. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Heat exchange or appliance blocked. Engineer to test pump.




Error Code: E2 350


Cause: Flow temperature sensor shorted. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check sensor and leads.




Error Code: E2 351


Cause: Flow temperature sensor disconnected. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check sensor and leads.




Error Code: FA 306


Cause: Ionisation detected after the gas valve closed. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check ionisation probe, leads and gas valve.




Error Code: EA 227


Cause: No ionisation detected after ignition. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check ionisation probe, leads and gas valve.




Error Code: F7 228


Cause: Ionisation current detected before burner start. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check ionisation probe, leads and gas valve.




Error Code: EA 229


Cause: Loss of ionisation signal during operation. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check ionisation probe, leads and gas valve.




Error Code: EA 261


Cause: Heat control module (HCM) potentially defective. Difficulty: 1 2 3 4 5 Engineer: Required. Solutions To Try: Site visit required by engineer.




Error Code: 9U 233


Cause: Control box or heat control module (HCM) is defective or loose, the HCM needs to be checked. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Check HCM.




Error Code: C4 237


Cause: Control box or heat control module (HCM) is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Check HCM.




Error Code: F0 238


Cause: Gas valve or control box error. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check gas valve.




Error Code: F0 239


Cause: Control box or the heat control module (HCM) is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Check HCM.




Error Code: F0 242


Cause: Control box or the heat control module (HCM) is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Check HCM.




Error Code: B7 257


Cause: Control box or the heat control module (HCM) is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check HCM




Error Code: F0 258


Cause: Control box or the heat control module (HCM) is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check HCM




Error Code: EH 258


Cause: Control box or the heat control module (HCM) is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check HCM




Error Code: F0 262


Cause: Control box or the heat control module (HCM) is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check HCM




Error Code: F1 259


Cause: Control box or the heat control module (HCM) is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check HCM




Error Code: F1 263


Cause: Control box or the heat control module (HCM) is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check HCM




Error Code: F0 272


Cause: Control box or the heat control module (HCM) is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check HCM




Error Code: F0 280


Cause: Control box or the heat control module (HCM) is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check HCM




Error Code: F0 290


Cause: Control box or the heat control module (HCM) is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check HCM




Error Code: 328


Cause: Internal error with the mains voltage. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check electrical connections.




Error Code: 235


Cause: Incompatible heat control module (HCM) software versions. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Control box needs latest software.




Error Code: 360


Cause: Heat control module (HCM) invalid. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check HCM




Error Code: 356


Cause: Low mains voltage. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: The voltage may be interrupted or inconsistent and needs checking.




Error Code: A8 362


Cause: Low mains voltage. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: The voltage may be interrupted, inconsistent or heat control module (HCM) invalid.




Error Code: A1 281


Cause: Pump stuck or running dry. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check pump and for air in system.




Error Code: D4 341


Cause: Primary flow temperature rising too fast. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Check for blockages and air in system.





Need an Engineer?

Plumber

Power Flush

From £250 + Vat

  • Removes Sludge

  • Improves Efficiency

  • Increases Boiler Life Span

Boiler Service

From £55 + Vat

  • Most Problems Fixed on Site

  • Gas, LPG and Electric

Emergency Call Out

No Call Out Charge!

  • 8.30am - 4.30pm

  • No Hidden Charges

  • Up To 20 Mile Radius

Need a Plumber?

Contact RP Plumbing & Heating today to book your engineer.

arrow&v

Registration No: 227159

RP Plumbing & Heating

About

FAQ

Portfolio

Location 

Contact

Get In Touch

47 Clifton Road

Poole

Dorset

BH14 9PW

07878 019 479

contact@rpplumbandheat.co.uk

Copyright 2020 RP Plumbing and Heating LTD Registered in England: 6428918 VAT: 925654995