Worcester Bosch Greenstar 8000 Series Boiler Error Codes

Including: All Variants

Find Your Error Code

Why does the 8000 series have so many error codes?


The 8000 series by Worcester Bosch is a "Smart Boiler". This boiler has more sensors and electronic inputs which lets it provide us with a more accurate description of what is going on. Unlike have 1 error code which may cover many issues, the 8000 has an error code for everything. This helps us diagnose problems fatser and saves you money!




Error Code: 200 O


Cause: Boiler in heating mode Difficulty: 1 2 3 4 5 Engineer: No Solutions To Try: Nothing to worry about. Currently in hot water mode.




Error Code: 201 O


Cause: Boiler in hot water mode Difficulty: 1 2 3 4 5 Engineer: No Solutions To Try: Boiler in hot water mode. Nothing to worry about.




Error Code: 202 O


Cause: Boiler in anti-cycle mode Difficulty: 1 2 3 4 5 Engineer: No. Solutions To Try: Boiler in anti-cycle mode. Nothing to worry about it.




Error Code: 203 O


Cause: Boiler in standby – no heat energy demand Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Visibly look for the spark




Error Code: 204 O


Cause: Current primary water temperature higher than set value Difficulty: 1 2 3 4 5 Engineer: No Solutions To Try: Water in tank is warmer than request. Nothing to worry about.




Error Code: 208 O


Cause: Chimney sweep demand. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Service mode option for engineer.




Error Code: 224 V


Cause: Safety temperature limiter has tripped. Difficulty: 1 2 3 4 5 Engineer: No Solutions To Try: Top-up water until the reset pressure is reached. If that doesn't work you may need an engineer to bleed the system and re-check the boilers status.




Error Code: 227 V


Cause: No flame signal after ignition. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer will need to check the burner control unit. Could need replacing.




Error Code: 228 V


Cause: Flame signal without flame present. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Check ionisation cable. Possibly needs replacing. Check gas control valve.




Error Code: 305 0


Cause: Boiler in hot water anti-cycle mode. Difficulty: 1 2 3 4 5 Engineer: No Solutions To Try: Nothing to worry about it.




Error Code: 306 0


Cause: Flame signal after closing the fuel supply. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check gas ratio control valve.




Error Code: 360 V


Cause: Incompatible code plug. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Check if a correct code plug is installed and exchange or reconnect code plug.




Error Code: 815W/B


Cause: Low loss header temperature sensor faulty. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check the sensor port or check the differential sensor for incorrect installation position or breakage. Correct the installation.




Error Code: 1010 O


Cause: No BUS communication cable, EMS-Bus isn’t connected or damaged. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to connect the cable for the EMS-Bus or replace the damaged cable exchange fuse.




Error Code: 1017 W


Cause: Water pressure too low. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: The water needs topping up and the vent system or pressure sensor may need replacing




Error Code: 1021 B


Cause: Hot water temperature sensor is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check the plug to the hot water temperature, sensor may not be connected.




Error Code: 1022 B


Cause: Hot water storage temperature sensor is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Connect the plug to the hot water temperature sensor correctly, mount the hot water temperature sensor correctly or replace the hot water temperature sensor.




Error Code: 1037 B


Cause: Outside temperature sensor is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Check the connecting lead.




Error Code: 1065 B


Cause: Pressure sensor defective or not connected. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Check pressure sensor connection as it may need replacing or cleaning.




Error Code: 1068 W


Cause: Outside temperature sensor defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Check the connecting lead.




Error Code: 1074 W


Cause: No signal from the flow temperature sensor available. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Connect the plug to the flow temperature sensor correctly or temperature sensor could need replacing.




Error Code: 1073 W


Cause: Short circuit of the flow temperature sensor. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check temperature sensor and check circulation in the sytem. May need replacing.




Error Code: 1075 W


Cause: Short circuit of the temperature sensor at the heating block. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Temperature sensor may need replacing.




Error Code: 1076 W


Cause: No signal from the temperature sensor at the heating block available. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer will need to check the connecting lead or the control unit. May need replacing.




Error Code: 2920 V


Cause: Error with the flame monitoring. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check connection, leads and flame detection probe.




Error Code: 2924 V


Cause: No feedback from the modulating gas valve. The gas valve relay is defective. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer will need to restart the boiler and check gas valve.




Error Code: 2925 V


Cause: Feedback from the modulating gas valve is too low. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer will need to check connection on gas valve.




Error Code: 2927 B


Cause: Flame failed during burner operation. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check gas inlet. Check elctrode, leads and flue system.




Error Code: 2946 V


Cause: Incorrect code plug detected. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Tthe code plug needs replacing.




Error Code: 2948 B


Cause: No flame signal. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check electrode, leads and burner assembly.




Error Code: 2950 B


Cause: No flame signal. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check electrode, leads and burner assembly.




Error Code: 2963 B


Cause: Signal from flow and heat exchanger temperature sensor outside the permissible range. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer will be required to check temprature sensor, connecting leads and circulation.




Error Code: 2965 B


Cause: Flow rate in heat exchanger is too low. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Flow temperature too high.




Error Code: 2964 B


Cause: Flow rate in heat exchanger is too low. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer will need to check for blockages or faulty heat exchanger.




Error Code: 2966 B


Cause: Flow temperature rise in heat exchanger too rapid. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer needs to check for blockages in system or boiler. Temprature sensors and heat exchanger will need checking also.




Error Code: 2970 B


Cause: Pressure drop in heating system too rapid. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Engineer to check connections on pressure sensor and check for leaks.




Error Code: 2967 B


Cause: Flow / heat exchanger temperature sensor differential too great. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: Check for air in the system, blockages and check sensors and heat exchange.




Error Code: 2971 B


Cause: System pressure too low. Difficulty: 1 2 3 4 5 Engineer: Required Solutions To Try: The heating system needs venting or water needs topping up until the preset pressure is reached. Replace the cable to the pressure sensor replace the pressure sensor.





Need an Engineer?

Plumber

Power Flush

From £250 + Vat

  • Removes Sludge

  • Improves Efficiency

  • Increases Boiler Life Span

Boiler Service

From £55 + Vat

  • Most Problems Fixed on Site

  • Gas, LPG and Electric

Emergency Call Out

No Call Out Charge!

  • 8.30am - 4.30pm

  • No Hidden Charges

  • Up To 20 Mile Radius

Need a Plumber?

Contact RP Plumbing & Heating today to book your engineer.